Commercial UPS 3P:3P (10-40kVA)

Commercial UPS 3P:3P (10-40kVA)

Real double conversion online technology

Online UPSs are an ideal choice especially for computers and other sensitive equipment. Online UPS completely isolates your equipment from the mains, charges its batteries from mains power and by using kinds of filters, supplies connected loads with power. As a result all unwanted conditions that may occur in mains are filtered by online UPS and your sensitive equipment is supplied with clean energy.

Real sine wave output

Fully compatible with all kinds of equipment. Ideal for medical and critical applications.

Wide input voltage range (120-276 VAC)

Online operation with very low and high voltages without using battery power.

  • Wide input voltage range (120-276 VAC)

Online operation with very low and high voltages without using battery power.

  • Input power factor correction (PF=0.99)

Reduces consumed electrical energy and yields saving in electric bills.

  • High output power factor (PF=0.9)

15% more power at the output in comparison to standard 0.7 power factor UPS systems. Can support more equipment.

  • Smart charger technology for optimum battery performance

Provides longer battery life and lower operational costs due to special charging technique.

  • High performance microprocessor

Because of its CPU control, digital structure and high speed; UPS performs overload, short circuit, low-high voltage and overtemperature protections. By providing complete protection ensures a stable and reliable operation.

  • In slim structure, with a capacity reachable to 40KVA

It gives possibility to put devices with high power, to narrow spaces such as server rooms.

  • High online efficiency

This UPS pays off its investment costs in a short period of time by reaching 93% efficiency level in average, through its developed technology. It means an electric bill with lower amount.

  • Structure available for parallel operation

This UPS has the property to be used in parallel operation, with no need for additional investment cost. A communication cable is sufficient for this.

  • Multi Funtion Buttons

-208/220/230/240 VAC Selectable Output Voltage
– 50/60 Hz Frequency Converter Mode
– ECO Mode High Energy Savings

  • Datacenter
  • Aiports
  • Factories
  • Emergency Power Systems
  • Smart Buildings
  • Security and Lighting Systems
  • Building Automation Systems and Special Telecommunication Applications
  • Hospitals
  • Construction Indusrty

The product is standard

Capacity
10kVA 15kVA 20kVA 30kVA 40kVA
Input
Phase 3 phase 4 wire and ground
Nominal voltage 380/400/415 VAC
Voltage range 208~478 VAC
Frequency range 45-55Hz de 50Hz/54-66Hz at 60Hz (auto sensing)
Current THDi  ≤3% (100% nonlinear load)
Bypass voltage range Max. voltage
Power factor ≥0.99
Output
Phase 3 phase 4 wire and ground
Nominal voltage 380/400/415 VAC,
Power factor 0.9
Voltage regulation ± 1%
Frequency Normal mode ± 1%, ± 2%, ± 4%, ± 5%, ± 10% of the rated frequency (optional)
Frequency Battery mode (50/60±0.2%) Hz
Crest factor 3/1
THD ≤2% with linear load, ≤5% with non linear load
Efficiency 93% 93% 93% 93,5% 94%
Battery
Voltage Standard unit.±120Vdc (20pcs 12V7Ah) (2x20pcs 12V9Ah optional) Long run unit Standard unit.±120Vdc (2×20 ad. 12V7Ah) Long run unit optional voltage. ±96V/±108V/±120Vdc (16/18/20pcs optional) Standard unit.±120Vdc (2×20 ad. 12V7Ah) Long run unit optional voltage. ±96V/±108V/±120Vdc (16/18/20pcs optional) Standard unit.±120Vdc (3×20 ad. 12V7Ah) Long run unit optional voltage. ±96V/±108V/±120Vdc (16/18/20pcs optional) Standard unit.±240Vdc (4×20 ad. 12V7Ah) Long run unit optional voltage.±192V/±204V/±216V/±240VDC (32/34/36/38/40pcs)
Charge current (A) (charge current can be set according to battery capacity installed Standard unit.1.35A (2.7A optional) Long run unit. Max. current 10A Standard unit. 2.7A Long run unit. Max. current 10A Standard unit. 4.5A Long run unit. Max. current 10A Standard unit. 4.5A Long run unit. Max. current 10A Long run unit. Max. current 10A
Transfer time Utility to battery. 0ms; Utility to bypass. 0ms
Protection
Overload AC mode Loads ≤110%. last 60min, ≤125%. last 10min, ≤150%. last 1min, >150% change to bypass immediately
Overload Battery mode Loads ≤110%. last 10min, ≤125%. last 1min, ≤150%. >150% shut down UPS immediately
Overload Bypass mode Breaker 20A Breaker 32A Breaker 40A Breaker 63A Breaker 80A
Short circuit 120 peak
Over temperature Line mode Switch to bypass, Backup mode
Battery low Alarm and switch off
Self-diagnostic Upon power on and software control
EPO (optional) Shut down UPS immediately
Battery Advanced battery management
Noise suppression Complies with EN62040-2
Dimensions & Weight
D x G x Y (mm) 828 x 250 x 868
Weight(kg) 115/57 170/63 171/64 223/71 280/73
Indicators & Alarm
Status LED & LCD Line mode, Bypass mode, Battery low, Battery bad, Overload & UPS fault
LCD panel Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage & Inner temperature
Audible & Visual Line failure, Battery low, Overload, System fault
Environmental
Operating temperature 0-40°C
Humidity 95% (non condensing)
Noise level ≤60dB ≤63dB ≤65dB ≤73dB ≤73dB
Management
Operating systems Windows® 98/2000/2003/XP/Vista/2008, Windows¨ 7/8, Linux, MAC
Interface RS 485, USB, Parallel (Optional), Dry contact, Intelligent slot, SNMP adapter (Optional), Relay card (Optional)